CPCB IV+ emission norms are mandatory for gensets up to 800 kW since July 2023Check if your genset complies
CPCB IV+ Approved Solutions
Temporary & Emergency Power•125 kVA to 2000+ kVA

Turnkey Rental Power Engineered for Rapid Industrial Deployment

Prevent assembly line halts, protect cold chain inventory, and power construction projects. AADEO Solvers delivers fully serviced, soundproof diesel generators with cabling, distribution switchgear, and dedicated on-site technicians across Delhi NCR and industrial zones.

Turnkey Package InclusionsMachine delivery + heavy-duty power cabling + changeover switchgear + 24/7 dedicated operator + routine servicing all consolidated into one fixed monthly tariff.
Application Scenarios

When Temporary Power is Mission-Critical

From scheduled substation servicing to urgent storm breakdowns, our rental fleet bridges electrical gaps seamlessly.

Planned Plant Shutdowns

Maintain continuous utility power during transformer maintenance, switchyard testing, or HT panel replacement.

Seasonal Production Surges

Support summer HVAC chiller loads or quarterly contract manufacturing surges without CapEx equipment purchase.

Construction & Greenfield Sites

Power batching plants, tower cranes, welding rigs, and site offices before permanent state utility grid connection.

Emergency Grid Failures

Rapid NCR mobilization to restore power after severe storms, cable faults, or catastrophic transformer blowouts.

Fleet Architecture

Rental Fleet Capacity Specifications

All units feature acoustic sound attenuation (<75 dBA), industrial silencers, integrated diesel tanks, and electronic governing.

Capacity BandVoltage / PhaseTypical Connected LoadsCabling ConfigurationRecommended Minimum Contract
125 kVA – 250 kVA415V, 3-Phase, 50 HzSmall manufacturing, retail hubs, commercial complexes1 run 3.5C x 240/300 sq.mm Al/Cu3 days / weekly / monthly
320 kVA – 500 kVA415V, 3-Phase, 50 HzHeavy processing lines, cold storages, hospitals2 runs 3.5C x 300 sq.mm XLPEWeekly / Monthly
750 kVA – 1000 kVA415V, 3-Phase, 50 HzLarge industrial plants, IT parks, tower cranes3-4 runs 3.5C x 400 sq.mm XLPEMonthly / Project-based
1250 kVA – 2000+ kVA415V or 11kV steppedData centres, utility substations, massive infrastructureCustom busduct or multiple parallel runsMonthly / Annual lease
Full Accountability

More Than A Machine Dropped at Your Gate

Renting a diesel generator often fails when delivery is disconnected from electrical hookup. Equipment sits idle while site managers search for certified electricians, proper lugs, and changeover panels. AADEO Solvers delivers end-to-end operational readiness.

Turnkey Electrical Hookup & Changeover

Our crew installs matched distribution cables, termination glands, and mechanical/electrical interlocked changeover switchgear.

24/7 Dedicated On-Site Operator

A trained technician monitors engine parameters (temperature, oil pressure, frequency, load balance) around the clock.

Routine Preventative Maintenance Included

All lube oil top-ups, filter replacements, and regular mechanical servicing are managed by AADEO at zero additional cost.

Rental Operational BenchmarksAADEO Guarantee

Emergency MobilizationRapid NCR Dispatch
Acoustic Canopy<75 dBA at 1 Metre
Operator Support24/7 Dedicated Crew
Maintenance Cost100% Covered in Tariff

Contract Flexibility

Zero long-term lock-ins for emergency requirements. Scale capacity up or down as project milestones evolve with predictable, transparent billing.

Rental FAQs

Frequently Answered Rental Power Questions

Transparent guidance on tariffs, cabling logistics, fuel supply, and environmental permissions.

What capacity range of rental diesel generators does AADEO Solvers deploy?
Our rental fleet spans from 125 kVA up to 2000+ kVA. Units can be deployed individually or synchronized in parallel multi-megawatt setups for large manufacturing plants, continuous process industries, data centre commissioning, and infrastructure projects.
How fast can AADEO Solvers mobilize a rental genset in Delhi NCR?
For emergency breakdowns and power outages in Gurugram, Delhi, Faridabad, Noida, and Greater Noida, our logistics and mobilization team dispatches rental units within rapid operational windows upon agreement. Planned rentals can be scheduled with dedicated advance site preparation.
What is included in AADEO's turnkey rental genset package?
Every rental deployment is a complete power solution: (1) Soundproof acoustic canopy genset, (2) Industrial power cables (up to standard connection distances), (3) Manual or automatic changeover switch (AMF/COS), (4) Earthing materials, (5) Skilled 24/7 on-site machine operator, and (6) Routine preventative maintenance and oil top-ups.
Can rental gensets be used during CAQM GRAP winter restrictions in Delhi NCR?
Yes, provided the equipment conforms to current CAQM directives. AADEO Solvers provides rental units equipped with compliant emission controls or dual-fuel systems as required by regional environmental authorities.
What are the rental billing structures (daily, monthly, project-based)?
We offer flexible contract terms: short-term emergency hire (daily/weekly for transformer servicing or events), monthly industrial hire (seasonal manufacturing peaks), and long-term project leases (6–24 months for greenfield infrastructure sites).
Direct Availability

Request Rental Rates & Immediate Fleet Dispatch

Provide your required kVA, site location, estimated duration, and connection distance. Our logistics coordinator will confirm available inventory and dispatch schedule.

1
Load assessment & generator capacity confirmation
2
Truck trailer dispatch with pre-tested cables & switchgear
3
On-site hookup, load verification & 24/7 operator deployment
Experiencing an active emergency blackout? Call our emergency line directly:
+91 9773555956
Service Needed *

We use your details only to respond to this enquiry. Privacy Policy.