CPCB IV+ emission norms are mandatory for gensets up to 800 kW since July 2023Check if your genset complies
CPCB IV+ Approved Solutions
Industry Focus · Data Centres & Critical IT Uptime

Tier N+1 Critical Continuous Uptime & ESD Server Environments

Ensure zero computational interruption with synchronized multi-megawatt diesel generators, precision distribution transformers, anti-static ESD flooring, and high-security facility visibility.

Tier N+1 / 2N
Redundant Synchronization
< 50 mbar
Zero Engine Derating RECD
ESD Protected
Anti-Static Dissipative Flooring
24/7 Triage
Mission-Critical Facility AMC
Mission-Critical Scope

Infrastructure Engineered for Five-Nines Reliability

Hyperscale and enterprise colocation centres require coordinated electrical and physical defenses against outages and environmental faults.

Tier N+1 Redundant Power & AMF

Prime and continuous diesel gensets (up to 3750 kVA) paired with automated synchronization switchgear and rapid AMF transfer, maintaining zero voltage sag to downstream UPS systems.

Anti-Static ESD Epoxy Flooring

Seamless conductive and dissipative floor coatings engineered to neutralize static build-up, protect sensitive micro-electronics, and eliminate particulate dusting in server halls.

Colocation CCTV & Lifecycle Care

Multi-angle IP surveillance for server rack aisles, UPS battery rooms, and perimeter gates with secure central recording, paired with dedicated preventive maintenance contracts.

Downtime Prevention

Vulnerabilities That Threaten 99.999% SLA Uptime

In computational environments, a split-second fault cascades into service outages and SLA penalties.

Extended Grid Outage Breaching Battery Reserve

UPS battery banks offer only 10 to 30 minutes of runtime. Without automated generator startup and synchronized parallel bus takeover, entire server rows shut down abruptly, risking transactional corruption.

Micro-Arcing from Electrostatic Discharge

Personnel walking across standard epoxy generate kilovolt static charges. A single discharge into a server rack can destroy motherboards or corrupt data buses. Our ESD coatings ground charges instantaneously.

Physical Security Audit Deficiencies

Enterprise colocation audits require continuous visual tracking across all server racks and hot/cold aisles. Blind spots or degraded recording quality can trigger non-compliance with SOC 2 and ISO 27001 physical standards.

Data Centre Technical Specifications

System parameters engineered to comply with mission-critical IT standards.

SubsystemHardware RatingVerified Specification & Compliance
Backup Generation125 kVA to 3750 kVA Multi-GensetsParallel load-sharing, AMF auto-switchover, Tier N+1 / 2N ready
Emission RetrofitRECD Units up to 910 kVACPCB-PCLS/12/2021-22 compliant, < 50 mbar backpressure tolerance
Server Room FlooringAnti-Static Conductive / Dissipative Epoxy10^4 to 10^9 ohms resistance, zero dusting, chemical wipe resistance
Perimeter & Aisle CCTVIP Network Surveillance & Multi-TB NVRHigh FPS, low-light infrared, corridor mode for narrow server aisles
Lifecycle SupportCritical Infrastructure AMCRoutine load bank testing, thermal imaging audits & rapid triage response
Rigorous Execution

Our Critical Facility Deployment Lifecycle

01
DISCOVER
UPS surge study, harmonic load survey & sub-floor static conductivity assessment
02
DESIGN
N+1 parallel synchronization topology, ESD grounding grid & CCTV floorplan
03
DELIVER
Staged equipment ingress, zero-dust floor grinding & panel positioning
04
COMMISSION
Integrated systems testing (IST), live failover simulation & static decay verification
05
SUPPORT
Planned breaker maintenance, RECD health logs & continuous technical upkeep
Direct Answers

Data Centre Power & Facility FAQ

Clear technical answers for data centre operators, IT directors, and facilities managers.

We design and supply heavy-duty diesel generator configurations (up to 3750 kVA) paired with fast-acting AMF switchboards and automated bus-tie synchronization panels. This ensures redundant generator capacity takes over instantly upon utility failure without interrupting downstream UPS systems or server racks.
Electrostatic discharge as low as 100 volts can silently degrade microprocessors, solid-state storage, and fiber transceiver modules. We apply certified ESD conductive and dissipative epoxy flooring systems that safely ground static charges and prevent airborne dust accumulation.
Yes. Our CPCB-PCLS/12/2021-22 compliant RECD retrofits are engineered with differential pressure sensors ensuring exhaust backpressure stays strictly below 50 mbar, preventing heat buildup and maintaining 100% prime power rating.
We deploy high-definition IP camera networks with low-light optical clarity, wide dynamic range, and edge analytics for server rack aisle monitoring, colocation cages, and perimeter access points with centralized NVR storage.
Our multi-discipline AMC includes periodic generator load-bank testing, breaker inspection, battery impedance monitoring, thermal imaging of electrical distribution panels, and sensor recalibration to avert downtime before it occurs.
Facility Review

Consult With Our Critical Infrastructure Specialists

Submit your facility capacity, Tier configuration, and ESD flooring needs. Our electrical and facility engineers conduct a technical review to design your solution.

Critical Facilities Desk
+91 9773555956
Amritansh@aadeo.in
Gurugram, India
Service Needed *

We use your details only to respond to this enquiry. Privacy Policy.